Resmed Lumis 150 VPAP ST


Resmed Lumis 150 VPAP ST

PERSONALISED VENTILATION MADE EASY

Lumis 150 VPAP ST is a noninvasive ventilator designed for non-dependent patients with obstructive or restrictive respiratory conditions.

Featuring ResMed’s unique volume-assurance mode – iVAPS (intelligent Volume-Assured Pressure Support) – Lumis 150 VPAP ST maintains target alveolar ventilation to suit each patient’s changing needs. And with an intelligent Backup Rate (iBR) and optional AutoEPAP, iVAPS continuously monitors ventilation and the upper airway.

The ventilator is easy to set up and use, and is supported by ResMed’s ResScan™ patient management software.


FEATURES

  • iVAPS learns each patient’s unique alveolar ventilation, sets appropriate targets, then provides smooth pressure support to suit.
  • intelligent Backup Rate (iBR)* gives patients maximum opportunity to trigger the ventilator. Staying out of the way until needed, iBR adds backup breaths to comfortably bring patients back to target. *Available in iVAPS and ST modes.
  • AutoEPAP** maintains upper airway patency by auto-adjusting the expiratory pressure in response to partial and full obstructions. **Available in iVAPS mode.
  • Vsync provides excellent patient–ventilator synchrony, even in the presence of significant leak.
  • TiControl™ lets you set min and max limits on either side of the patient’s ideal inspiratory time to encourage spontaneous breathing.
  • Trigger and cycle helps you optimise settings according to the patient’s condition, using five trigger and cycle sensitivity levels.
  • QuickNav for low-touch therapy adjustment. By simply double-clicking the home button on the device, you can toggle between the Settings and Monitoring screens to change and check settings quickly and easily.
  • Climate Control Auto for automatic humidification. When used with a HumidAir™ heated humidifier and ClimateLineAir™ heated tube, Lumis delivers humidification automatically – no settings to change and no complicated menus to navigate.
Modes Available CPAP, S, T, ST with optional iBR, PAC, iVAPS with iBR and optional AutoEPAP
Operating pressure 2–25 cm H2O (2–25 hPa) in S, T, ST, PAC and iVAPS modes 4–20 cm H2O (4–20 hPa) in CPAP mode
Sound pressure level 26.6 dBA with uncertainty of 2 dBA as measured according to ISO 17510-1:2009 (CPAP mode)
Operating temperature/ humidity/altitude +5°C to +35°C/ 10–95% relative humidity, non-condensing/ Sea level to 2,591 m; air pressure range 1013 hPa to 738 hPa
Dimensions (L x W x H) 116 mm x 205 mm x 150 mm
Weight 1.10 Kg
Power Consumption Input range: 100–240V, 50–60Hz, 57VA (typical power consumption) 108VA (peak power consumption)