Isleep 25 by Breas


Isleep 25 by Breas

Thanks to eSync, Breas’ highly responsive Trigger technology, iSleep 25 synchronizes smoothly with the patient’s breathing effort. As the patient demands for a new breath, iSleep 25 responds immediately and delivers the pressure required, allowing for very comfortable breathing. Backup frequency guarantees ventilation to patients during central apneas or intermittent hypoventilation. By adjusting rise time and eSync, physicians can match the iSleep 25 settings to the patient’s needs. And with memory card capability, it’s quick and easy to download long-term patient compliance data and detailed log.


Features:

Integrated heated humidifier that offers adjustable upper airway humidification for increased compliance

An enhanced user interface that provides comprehensive information on therapeutic data

A user-friendly hose, connected to the rear of the unit; it can easily be positioned using the built-in swivel

Adaptable for use with a wide range of masks

Lightweight design and the built-in carrying handle for easy travel.

Power adapter. With the DC/DC converter, the unit can be powered from a car or recreational vehicle when enjoying an active everyday life

SpO2 monitoring possibility.

Settings/Performance
  • Ventilation Modes: CPAP, Bi-Level
  • Device Modes: Clinical, Home
  • IPAP: 4 to 25 cmH2O
  • EPAP: 4 to 20 cmH2O
  • CPAP: 4 to 20 cmH2O
  • Expiratory Trigger: 1 to 9, Auto
  • Breath Rate: 1 to 5 BPM
  • Rise Time: 1 to 5
  • Rise Time: 1 to 9
  • Back-up Rate: 4 to 30 bpm
  • Maximum Flow:
  • at 1/3 of max pressure: 108 litres/min
  • at 2/3 of max pressure: 132 litres/min
  • at max pressure: 132 litres/min
  • Maximum limited pressure during single fault condition: 30 cmH2O (CPAP) or 40 cmH2O (Bi-Level)
  • Breathing resistance under single fault condition:
  • 0.9 cmH2O at 30 litres/min
  • 3.2 cmH2O at 60 litres/min
  • Digital output: Yes (0 to 5v)
  • Sound level at 10 cmH2O: Less than 30 dB(A)
Indications
  • Internal function failure: Message on the display + Audible Signal
  • Power failure indication: Message on the display + Audible Signal
  • Monitoring: Pressure, Leakage, Tidal Volume, I:E Ratio, Triggered breaths, Breath Rate
  • High Pressure Alert / High Leakage Alert: On/Off.
  • Alarms
  • Audible Alarm Level: 35 to 85 dB(A)
  • Low/High pressure alarm, Low volume alarm, Low/High leakage alarm, Low external DC Warning, Low power alarm, Internal function failure alarms.
  • Power Supplies
  • Mains supply: 100 to 240 V AC
  • External DC supply: 24 V DC, 12V adapter available
  • Operating Conditions
  • Recommended mask leakage: 20 to 40 litres/min at 10 cmH2O
  • Minimum mask leakage: 12 litres/min at 4 cmH2O
  • Dimensions
  • W x H x D: 173 x 172 x 209 mm (without HA20)
  • Weight: 2,0 kg
  • Air outlet: 22 mm conical standard connector